Calibration/setup document: Basic setup for a B&G Hydra/Hercules System (good luck reading and understanding this) http://www.bandg.com/upload/BandG/Documents/Manuals/newh2000proc.pdf (S/N H374001 and higher) H2000 Hydra Basic SetupDEPTH -> DEPTH ==> CALIBRATE -> DATUM SPEED -> BOAT SPD ==> CALIBRATE -> MANL CAL -> SINGLE (or use AUTO CAL) WIND -> MEAS W/A ==> CALIBRATE -> MHU ANGL (or sometimes APP W/A) NAVIGATE -> COURSE ==> CALIBRATE -> CAL VAL1 -> HEADING NODE NAVIGATE -> D/R COURSE ==> CALIBRATE -> CAL VAL1 -> HEADING NODE (5, 9, 15,16,17,18 or 96,97,...) heading node 9 is NMEA through Performance Processor instead of FFD NAVIGATE -> HEADING ==> CALIBRATE -> CAL VAL 1 -> HEADING OFFSET MOTOR -> VOLTS ==> CALIBRATE -> CAL VAL 1 For better wind data, enter the correction table found in the X35 tuning guide http://www.skilux.fi/Link.aspx?id=1009319 WIND -> TRUE W/A ==> CALBRATE -> CORRECTION WIND -> TRUE W/S ==> CALBRATE -> CORRECTION Further, change the DAMPING of some functions, depending on the wind conditions H2000 Pilot SetupTo enter setup, press both < and > next to COURSE (3rd row of buttons) Enter all data (B TYPE=SAIL, H SRC=18, H OFF=0,DIP=2,DRIVE=A, S CAL=6.25,B LEN=12.0,B LAG=0.30,R GAN=2) RUD P = rudder Port, RUD S = rudder Starboard, RUD M=mid and then select RUD T, this will determine the time from Port to Starboard Sea Trial: Do a compass SWING, make a slow 360, later test the system by changing the boat direction by 90 or 120 degrees and determine boat lag. During Sailing, select RESP and choose between ECON, NORMAL or DOWNWIND for more quicker response http://www.bandg.com/upload/BandG/Documents/Div/hpilot.pdf (pre July 2004) H2000 Performance SetupNAVIGATE -> LEEWAY ==> CALIBRATE -> CAL VAL1 = Factor K (between 8 and 10 on a fast yacht?) PERFORMANCE -> HEEL ==> CALIBRATE -> CAL VAL 1 -> OFFSET PERFORMANCE -> TRIM ==> CALIBRATE -> CAL VAL 1 -> OFFSET For entering your performance data, use a program like Deckman or Expedition, which will save you a lot of work. Other TipsUpgrade to the latest system EPROMs, check the versions: Reset system http://primus.bandg.com/icrbg/BandG%20FAQs/H2000%20FAQS/FAQ%20-%20Hydra-Herc%20-Reset%20Function.pdf FFD Quick Reference Shutdown Alarm press the ENTER key twice to silence the audible alarm. 20/20 programming (temporary and fixed) Lock FFD press ENTER and LIGHTS, to lock all except page key, again to lock all, again to unlock Change pages on FFD See manual |