FASTNET COMMANDS

Command Description Bytes
00 This maybe a ARP request to see if my node address is in use. (used at start up) or  Reset Command
01 This appears to be a normal broadcast data command Var
02 New Text ?
03 Sent from an NMEA FFD when NMEA data is there.    ff 60 02 03 50 47  or 47 50 2
04
05
06
07
08
09
0A Used at start up?? 2
0B
0C This looks like a keep alive message, sent from FFD, 1 byte, ff 60 0C 6f 1
0D
0E
0F
10
20 Sector Alarm
21 Alarm, low alarm off, 60 01 21 ss 41 24 03 00 00 00 7
22 Alarm , hi alarm off , 60 01 22 ss 41 24 04 00 00 32 7
68 Request for data, reply is 6A, 2 bytes in request, 00 03, ask for version number 2
6A Reply from a 68 request.. (FFD do not respond to this), replay is 4 bytes, 00 03 xx xx 4
C8 FFD send this when powering off
C9 Used to set light intensity in FFD and 20/20, two bytes of data, 1st: 0,1,2,4, 2nd byte always 20h, 0 = off, 4 = max 2
CA Timer, 2 bytes, From FFD, start 10 = 05 60 CA ss FD, start 5, FE, start zero, FF
CB Timer, 2 bytes, From FFD, Frezze, Run, Halt 2
CC Timer Run, 2 bytes 2
CD Request Damping value   01 60 CD ss 59 2
CE Set/Get damping value   60  01 CE ss 41 21 00 5E   (94) 5
CF From FFD, Manual Cal request, 01 60 CF  ss 41 2
D0 From FFD , send reaching correct, 05 60 D0 ss 59 04, respond is a D4 3
D1 Ask for cal 2?
D2
D3 Cal 1, 60 01 D3  ss 41 91 02 71, => 6.25, 41 = boatspeed,  Depth sends 60 01 D3 ss 41 06 00 f8 60 60 (respond to auto cal) 5 or 7
D4 Cal 2, respond to a D0, 60 05 D4 ss 59 54 04 00 00 00 7
D5 Cal 3
D6 Cal 4
D7
D8
D9
DA
DB
DC Timer Freeze from FFD, 2 bytes   01 60 DC ss CF, respon from 01 is FD, 60 01 FD ss 35 2
DD
DE Alarm low off, 01 60 DE ss 41
DF
E0
E1
E2 Alarm low on,  01 60 E2 ss 41 (boat speed)
E3
E4
E5 1
E6 Alarm off, ff 60 E6 ss
E7
E8
E9 Set/Get Cal value, 60 01 E9  ss 41 91 00 64   64=1.00 5
EA Start a cal run, Boat speed, 01 60 EA  ss 41, ack with an FD from FFD 2
EB Stop a cal run, Boat speed, 01 60 EB  ss 41, ack with an FD from FFD 2
EC End Cal run, 01 60 EC ss 41 D3,  Depth sends 60 01 D3 ss 41 06 00 f8 60 60 3
ED Cal    FD 60 ED  26
EE From FFD, request Cal value 41,   01 60 EE   ss 41, 41 = boatspeed
EF From FFD, ask what meter is connected. FD 60 EF ss 01, what on meter 01 2
F0 From FFD/Processor , to chang meters display, FD 60 F0 ss  01 03, set meter 01 to Mag Wind 03 3
F1 From FFD, Max Value, , 1st byte = seq, 2nd = 00 = Boat Speed, 01 = Wind Speed, FD 60 F1 01 00 or FD 60 03 01 2
F2 Set/Get max value, FD 60 F2  07 00 51 00 78, new max wind is 120 or 12.5 5
F3
F4
F5
F6
F7
F8
F9
FA ack for FC??
FB
FC Used on start up to assign channels, ie: this node will send this data Var
FD ack for FC from FFD, 1 byte look like sequence # to ACK 1
FE
FF FFD send on start up,waiting to see if some one is on the net, 0 bytes 0